Article Text

Download PDFPDF

Response to: “Rise of the machines”: human factors and training for robotic-assisted surgery
  1. Jessica Butterworth1,
  2. Margaux Sadry1,
  3. Danielle Julian2 and
  4. Fiona Haig1
  1. 1CMR Surgical Ltd, Cambridge, UK
  2. 2AdventHealth, Altamonte Springs, Florida, USA
  1. Correspondence to Ms Fiona Haig; fiona.haig{at}cmrsurgical.com

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

We thank Kerray and Yule for their Editorial on our evaluation of a training program developed specifically for Versius, a next-generation system for robot-assisted minimal access surgery (MAS).1 We have found the points raised, particularly those pertaining to validity frameworks and human factors, to be constructive, providing valuable guidance for future studies evaluating the effectiveness of trainings in the surgical setting.

The program we described is intended to provide surgeons with practical experience operating the system in a simulated environment and is not focused on a specific surgical specialty or procedure.2 As such, the aim of the study was to monitor performance using the system as surgeons became more familiar and practiced using the system over the course of the program. The use of Global Evaluative Assessment of Robotic Skills (GEARS) scoring provided a validated means of quantifying performance across a range of tasks to allow comparison between surgeon subgroups and timepoints.3 The proficiency levels were determined from the literature only to help contextualize GEARS scores, not to ascertain operating proficiency for individual surgeons using the system.

The features of the device noted in the study publication provide specific examples of how aspects of the design may help remove some of the barriers to uptake of MAS by minimizing the limitations often associated with conventional MAS instruments. Increasing uptake of MAS by incorporating robotic assistance to help improve patient outcomes compared with open surgery was the fundamental driver behind the device’s conception and development; the advantages of MAS over open surgery are numerous and well established, yet MAS utilization has been lower than anticipated hitherto across several common procedures.4 Cooper et al also note that lack of specific training and exposure to MAS techniques may be partly attributable to the low uptake.4 We anticipate that purpose-designed training programs such as this one will play an important role in realizing the vast potential of robotic systems as the field evolves.

While implementation of Kirkpatrick’s validity framework could have informed the study design to help better address criteria within levels 1 and 3, level 4, assessing the impact of the training on surgical outcomes and safety, was not within the scope of this study as this is only possible in the clinical setting.5 Ongoing systematic collection of clinical effectiveness and safety data into a purpose designed registry will facilitate longer-term monitoring and large-scale analyses of outcomes, in line with IDEAL-D recommendations.6

As noted by Kerray and Yule,1 surgeons with experience using other robotic systems may require more training to adjust to a new platform compared with surgeons with no prior robotics experience. As this surgical system is unique, a transference study is planned to investigate how training needs may differ and how the program could be tailored according to the level of prior experience in performing robot-assisted surgery. As also suggested in the Editorial,1 human factors, such as leadership and teamwork, including surgeon–team communication, are currently being integrated into the program to ensure the training encompasses all aspects of robot-assisted surgery required for optimal performance. This process is ongoing, and human factors must be tailored to this device specifically given its novel architecture.

Given the lack of validated training programs to support the implementation of robotic systems in surgery, we thank Kerray and Yule for their helpful recommendations for future evaluations.

Ethics statements

Patient consent for publication

Acknowledgments

The authors acknowledge Mark Slack, MBBCh Mmed FCOG (SA) FRCOG, from CMR Surgical, for publication coordination and critical input to the intellectual content of this Response during its development. The authors also acknowledge Oliver Palmer, BSc (Hons), and Emma Phillips, PhD, from Costello Medical, UK, for medical writing and editorial assistance based on the authors’ input and direction.

References

Footnotes

  • Contributors Substantial contributions to drafting the article or revising it critically for important intellectual content: JB, MS, DJ, FH. Final approval of the version of the article to be published: JB, MS, DJ, FH.

  • Funding Support for this response was funded by CMR Surgical in accordance with Good Publication Practice (GPP3) guidelines (http://www.ismpp.org/gpp3).

  • Competing interests MSlack is Chief Medical Officer and Co-Founder of CMR Surgical. JB, MSadry, and FH are employees of CMR Surgical. DJ is an employee of AdventHealth.

  • Provenance and peer review Commissioned; internally peer reviewed.

Linked Articles