Abstract
We report a case of late type III B endoleak from a fabric tear in the main body of a Zenith bifurcated stent-graft approximately 19 months after implantation. A follow-up computed tomography (CT) scan showed gradual growth in the size of the aneurysm, but no apparent endoleak was recognized. However, the CT scan had demonstrated a mosaic pattern in the aneurysm sac, which could indicate an endoleak from a fabric tear. The defect was repaired by implantation of body extensions, but the patient died 5 h after the procedure.
Similar content being viewed by others
References
Parodi JC, Palmaz JC, Barone HD. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg. 1991;5(6):491–9.
White GH, Yu W, May J. Endoleak—a proposed new terminology to describe incomplete aneurysm exclusion by an endoluminal graft. J Endovasc Surg. 1996;3(1):124–5.
White GH, Yu W, May J, Chaufour X, Stephen MS. Endoleak as a complication of endoluminal grafting of abdominal aortic aneurysms: classification, incidence, diagnosis, and management. J Endovasc Surg. 1997;4(2):152–68.
White GH, May J, Waugh RC, Chaufour X, Yu W. Type III and type IV endoleak: toward a complete definition of blood flow in the sac after endoluminal AAA repair. J Endovasc Surg. 1998;5(4):305–9.
Teutelink A, van der Laan MJ, Milner R, Blankensteijn JD. Fabric tears as a new cause of type III endoleak with Ancure endograft. J Vasc Surg. 2003;38(4):843–6.
Brown KE, Heyer KS, Matsumura JS, Eskandari MK. Late Type III endoleak and graft failure of an Ancure stent-graft. J Vasc Interv Radiol. 2008;19(10):1506–8.
Lee WA, Huber TS, Seeger JM. Late type III endoleak from graft erosion of an Excluder stent graft: a case report. J Vasc Surg. 2006;44(1):183–5.
Wanhainen A, Nyman R, Eriksson MO, Björck M. First report of a late type III endoleak from fabric tears of a Zenith stent graft. J Vasc Surg. 2008;48(3):723–6.
Juszkat R, Staniszewski R, Zarzecka A, Majewski W. Diagnosis of type III endoleak and endovascular treatment with aortouniiliac stent-graft. J Vasc Interv Radiol. 2009;20(1):125–9.
Hori D, Yuri K, Nemoto K, Yamaguchi A, Adachi H. Successful treatment of an abdominal aortic aneurysm by endovascular graft placement through a previously placed prosthetic graft: report of a case. Surg Today. 2010;40(12):1169–72.
Cao P, De Rango P, Verzini F, Parlani G. Endoleak after endovascular aortic repair: classification, diagnosis and management following endovascular thoracic and abdominal aortic repair. J Cardiovasc Surg (Torino). 2010;51(1):53–69.
Stavropoulos SW, Charagundla SR. Imaging techniques for detection and management of endoleaks after endovascular aortic aneurysm repair. Radiology. 2007;243(3):641–55.
Conflict of interest
Hiroshi Banno and his co-authors have no conflict of interest.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Banno, H., Morimae, H., Ihara, T. et al. Late type III endoleak from fabric tears of a zenith stent graft: report of a case. Surg Today 42, 1206–1209 (2012). https://doi.org/10.1007/s00595-012-0320-8
Received:
Accepted:
Published:
Issue Date: