Table 2

Clinical events before (2011-2013) and after (2015-2017) introduction of force-sensing catheters.

Before (2011–2013) n=3470 (%)After (2015–2017) n=5772 (%)P value
30-day events
AEF0.00.01
 Definite0.00.01
 Probable0.00.01
 Sensitivity1.10.90.247
Death0.20.10.309
Tamponade or intervention0.20.30.321
Pericarditis1.41.50.735
Stroke/TIA0.10.10.630
Hospitalization or ED visit18.116.80.134
90-day events
AEF0.040.090.379
 Definite0.040.040.942
 Probable0.040.070.580
 Sensitivity2.21.60.039
Death0.50.30.226
Tamponade or intervention0.40.50.494
Pericarditis1.71.80.675
Stroke/TIA0.20.20.960
Hospitalization or ED visit27.023.90.001
  • AEF, atrioesophageal fistula; ED, emergency department; TIA, transient ischemic attack.